In line detonation flame arresters

G 5 N Uni-directional in-line detonation flame arrester

KITO® Rd/C-Det4-IIA-…-1.2 Detonation flame arrester for installation into pipes to protect containers and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion groups IIA1 to IIA with a maximum experimental safe gap (MESG) > 0.9 mm. An operating pressure of …

G 5 N Uni-directional in-line detonation flame arrester Read More »

G 12 N Detonation proof foot valve

KITO® NRV-…-IIB3 For end of line service, detonation proof, valve with superposed valve pallets for installation into suction pipes of underground tanks in which inflammable liquids of explosion group IIA1 to IIB3 with a maximum experimental safety gap (MESG) ≥ 0.65 mm and an maximum operating temperature of 60 °C are stored. Tested and approved …

G 12 N Detonation proof foot valve Read More »

G 13.0 N Uni-directional in-line liquid detonation flame arrester

KITO® FL/E-…-IIB3 (wf) -maintenance-friendly and easy to clean design- As inline armature, detonation-proof and flameproof, used for installation in filling and suction pipes outside from tanks in which inflammable liquids are stored. Tested and approved as detonation flame arrester type 4. Approved for all materials of the Explosion group IIA1 to IIB3 with MESG ≥ …

G 13.0 N Uni-directional in-line liquid detonation flame arrester Read More »

G 13.1 N Uni-directional in-line liquid detonation flame arrester

KITO® FL/EO-…-IIB3 as inline armature, detonation-proof and flameproof, used for installation in filling pipes outside from tanks in which inflammable liquids are stored. Tested and approved as detonation flame arrester type 4. Approved for all materials of the explosion group IIA1 to IIB3 with MESG ≥ 0.65 mm and an maximum operating temperature of 60 …

G 13.1 N Uni-directional in-line liquid detonation flame arrester Read More »

G 13.2 N Uni-directional in-line liquid detonation flame arrester

KITO® FL/EO-…-IIB3 (wf) -maintenance-friendly and easy to clean design- as inline armature, detonation-proof and flameproof, used for installation in filling pipes outside from tanks in which inflammable liquids are stored. Tested and approved as detonation flame arrester type 4. Approved for all materials of the explosion group IIA1 to IIB3 with MESG ≥ 0.65 mm …

G 13.2 N Uni-directional in-line liquid detonation flame arrester Read More »

G 13 N Uni-directional in-line liquid detonation flame arrester

KITO® FL/E-…-IIB3 As inline armature, detonation-proof and flameproof, used for installation in filling and suction pipes outside from tanks in which in-flammable liquids are stored. Tested and approved as detonation flame arrester type 4. Approved for all materials of the explosion group IIA1 to IIB3 with MESG ≥ 0.65 mm and an maximum operating temperature …

G 13 N Uni-directional in-line liquid detonation flame arrester Read More »

G 14.1 N Uni-directional end-of-line liquid detonation flame arrester

KITO® FL/INO-…-IIB3 As end-of-line armature, detonation and flame proof, used for mounting on the pipes end of filling pipes inside of tanks in which inflammable liquids of the explosion groups IIA1 to IIB3 are stored with a nominal gap width (MESG) of ≥ 0.65 mm and an maximum operating temperature of 60 °C. Tested and …

G 14.1 N Uni-directional end-of-line liquid detonation flame arrester Read More »

G 14 N Uni-directional end-of-line liquid detonation flame arrester

KITO® FL/IN-…-IIB3 As end-of-line armature, detonation and flame proof, used for mounting on the pipe end of filling and discharging pipes inside of tanks in which inflammable liquids of the explosion groups IIA1 to IIB3 are stored with a nominal gap width (MESG) of ≥ 0.65 mm and an maximum operating temperature of 60 °C. …

G 14 N Uni-directional end-of-line liquid detonation flame arrester Read More »

G 18.1 N Uni-directional in-line detonation flame arrester, short-time burning proof

KITO® FDN-Det4-IIA-…-1.2 KITO® FDN-Det4-IIA-…-1.2-T For installation into pipes to protect containers and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion groups IIA1 to IIA with a maximum experimental safe gap (MESG) > 0.9 mm. Working unidirectional in pipes, whereby …

G 18.1 N Uni-directional in-line detonation flame arrester, short-time burning proof Read More »

G 18.2 N Uni-directional in-line detonation flame arrester, short-time burning proof

KITO® FDN-Det4-IIB3-…-1.2 KITO® FDN-Det4-IIB3-…-1.2-T For installation into pipes to protect containers and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion groups IIA1 to IIB3 with a maximum experi-mental safe gap (MESG) ≥ 0.65 mm. Working unidirectional in pipes, whereby …

G 18.2 N Uni-directional in-line detonation flame arrester, short-time burning proof Read More »